Fique por Dentro das Novidades
Receba ofertas exclusivas e lancamentos diretamente no seu e-mail.
2 produtos encontrados

Lysing Matrix A 50 mL tubes contain garnet matrix and fifty 1/4" ceramic spheres. Application Notes Lysing Matrix A is used for all sample types, except soil, for the subsequent isolation of genomic DNA and proteins. Usage Statement Unless specified otherwise, MP Biomedical's products are for research or further manufacturing use only, not for direct human use. For more information, please contact our customer service department. Key Applications Nucleic Acid Isolation, Nucleic Acid Extraction, Proteomics, Purification and Detection, Protein Purification, DNA Purification, Plant Tissue Processing, Tissue Analysis, Bacterial Lysis, Yeast Lysis, Fungal Tissue Analysis, Animal Cell Lysis, Animal Tissue Analysis, Microbiome Studies, Metabolite Extraction, Grind Seeds, Homogenization SKU 116950002-CF Alternate Names A Matrix Application Notes Lysing Matrix A is used for all sample types, except soil, for the subsequent isolation of genomic DNA and proteins. Average Size Zirconium sphere, 6.35 mm, Garnet Flakes, 0.56 - 0.7 mm Base Catalog Number 6950002 Bead Material Garnet (flakes) Bead Size 0.56 - 0.7 mm Capacity 50 mL FastPrep Instruments Models ConeFlex Legacy (allows all FP24 adapters on FP96), BigFlex (8x50 mL), BigPrep (2x50 mL), CoolBigPrep (2x50 mL), All Metal BigPrep (2x50 mL) Format 50 mL tube Hardness Zirconium sphere: Rockwell A 80-84, Vickers 1050, Garnet Flakes: Mohs 7.5-8 Molecular Formula Banded Satellite: ZrO 2 88%, CeO 10%, Garnet: Fe 3 Al 2 (SiO 4 ) 3 Personal Protective Equipment If working with biological, toxic, hazardous or infectious samples use hand protection (Latex, Nitrile or other protective approved material gloves), skin and body protection (labcoat and long-sleeves) and eye protection (safety glasses with side-shields). Handle in accordance with good industrial hygiene and safety practices. Sample Type Bone, Heart, Lung, Seeds, Skeletal Muscle, Spores, Feces, Food, Fungi, Plants, Roots, Soil, Wastewater, Yeast, Sludge, Animal Tissue, Bacteria (Gram (+/-), Fixed Samples, Hair, Tooth, Tumor Sample Volume up to 7 g per prep Specific Gravity Zirconium sphere: 5.5 - 6.1 |Garnet Flakes: 4.0 - 4.1 Usage Statement Unless specified otherwise, MP Biomedical's products are for research or further manufacturing use only, not for direct human use. For more information, please contact our customer service department.
R$ 2.683,02

TallPrep™ Lysing Matrix Z, 4.5 mL Tube contains 0.5 mm diameter Yttria-Stabilized Zirconium Oxide beads. Will not bind nucleic acids. Application Notes Lysing Matrix Z is used primarily for lysis of animal and plant tissue, tougher stems, roots and seeds, and whole insects. Matrix Z is an alternative to the very agressive Matrix A in applications such as RNA and Protein isolation from very tough tissue. Usage Statement Unless specified otherwise, MP Biomedical's products are for research or further manufacturing use only, not for direct human use. For more information, please contact our customer service department. Key Applications Nucleic Acid Isolation |Nucleic Acid Extraction |Cell culture |Proteomics |Purification and Detection |Protein Purification |DNA Purification |RNA Purification |Plant Tissue Processing |Tissue Analysis |Soil Analysis |Fungal Tissue Analysis |Microbiome Studies |Metabolite Extraction |Tissue Homogenization |Isolate Intact Organelles |RNA Extraction from Difficult Samples |Isolation of Intact Bacteria and Viruses from Infected Tissue SKU 116985025-CF Alternate Names Tall Z Matrix Application Notes Lysing Matrix Z is used primarily for lysis of animal and plant tissue, tougher stems, roots and seeds, and whole insects. Matrix Z is an alternative to the very agressive Matrix A in applications such as RNA and Protein isolation from very tough tissue. Average Size 1.5 - 2.0 mm Base Catalog Number 6985025 Bead Material Yttria-stabilized zirconium oxide Bead Size 0.5 mm Capacity 4.5 mL FastPrep Instruments Models ConeFlex Legacy (allows all FP24 adapters on FP96), TallFlex (48x4.5 mL), TallPrep (24x4.5 mL) Format 4.5 mL tube Hardness Mohs 9 |Rockwell A >87 |Vickers >1350 Molecular Formula ZrO2 95%, Y2O3 5% Personal Protective Equipment Personal-protective-equipment: If working with biological, toxic, hazardous or infectious samples; Hand protection: Latex, Nitrile or other plastic material gloves. Skin and body protection: Labcoat and sleves. Eye protection: Safety glasses with side-shields Hygiene measures: Handle in accordance with good industrial hygiene and safety practice. Sample Type Animal Tissues, Cultured Cells, Kidney, Liver, Plant Tissue, Soft Tissue Sample Volume up to 0.5 g per prep Specific Gravity 6.02 Usage Statement Unless specified otherwise, MP Biomedical's products are for research or further manufacturing use only, not for direct human use. For more information, please contact our customer service department.
R$ 2.280,84 - R$ 6.422,22